About the DD-F Series
The DanVex DD-F Series is a range of compact ducted dehumidifiers for residential and small-commercial environments where a single concealed unit must deliver humidity control, fresh-air intake and high-grade filtration together. Capacity runs from 32 L/day (DD-36F) to 155 L/day (DD-136F) with supply airflow of 410–1150 m³/h — all on single-phase 220–230 V, with no need for a three-phase supply.
Every unit is built around a two-inlet / one-outlet airflow architecture: one duct for recirculated return air from the room, and a second for fresh outdoor-air intake controlled by an automatic valve. The two streams mix inside the unit, pass through a G4 pre-filter and a HEPA H13 final filter, are dehumidified, sterilised by a UV lamp and delivered through a single supply outlet. A 5-in-1 sensor on the return stream continuously monitors CO₂, PM2.5, TVOC, humidity and temperature — the unit adjusts the fresh-air valve and operating mode to indoor air quality, not just the humidity set-point.
Each unit pairs an inverter compressor with an inverter fan (Full Inverter) and an electronic expansion valve (EEV) — compressor and fan continuously adjust output to the actual load and stabilise airflow, while the EEV meters refrigerant precisely for peak circuit efficiency. For quiet operation the housing uses pyramid-profile acoustic insulation that absorbs compressor vibration rather than merely containing it. Standard across the range: Hot Gas Defrost, E-Coating, internal Antifungus treatment, R-32 refrigerant and Modbus RTU RS-485 + Wi-Fi connectivity. The Ultra-Slim housing installs invisibly in the ceiling void — only the grilles show in the finished room. Noise below 32 dB(A) on DD-36F / DD-56F and below 35 dB(A) on DD-96F / DD-136F — suitable for bedrooms, clinics and offices.
Slide-out module maintenance. In conventional dehumidifiers, maintenance becomes a problem once faults begin: repair usually means calling an expensive licensed specialist for refrigerant-containing equipment, electrical and brazing work (not permitted everywhere), or removing the whole unit. The DD-F is designed to make repair simple: the compressor, main control board, heat exchangers and refrigerant piping sit together in a single slide-out cassette that pulls out of the housing for service, repair or replacement. One technician disconnects the main module and fits a replacement in about 15 minutes, and the unit runs as new — fast service without dismantling installed equipment.
Models in the range
DD-36F 32–44 L/day · 410–500 m³/h supply · 0–200 m³/h fresh · 120 Pa · 62 kg · Full Inverter · HEPA H13
Indicative coverage: ~50–90 m² depending on conditions
For small residential and compact commercial spaces: studio apartments, small offices, dental and medical consulting rooms, single hotel rooms, allergy-sensitive nurseries. Variable power 460–850 W, R-32 × 550 g. Noise below 32 dB(A).
DD-56F 45–75 L/day · 450–600 m³/h supply · 0–200 m³/h fresh · 120 Pa · 67 kg · Full Inverter · HEPA H13
Indicative coverage: ~80–130 m² depending on conditions
For medium residential and small commercial use: family apartments, larger living spaces, small clinics, retail outlets, classrooms, asthma-sensitive environments. Variable power 550–970 W, R-32 × 600 g. Noise below 32 dB(A).
DD-96F 98–145 L/day · 650–870 m³/h supply · 0–300 m³/h fresh · 150 Pa · 69 kg · Full Inverter · HEPA H13
Indicative coverage: ~130–200 m² depending on conditions
For large residential and small commercial use: large family homes, basements with moisture load, medical clinics, dental practices, small server rooms, luxury hotel suites. Variable power 920–1260 W, R-32 × 720 g. Noise below 35 dB(A).
DD-136F 110–155 L/day · 800–1150 m³/h supply · 0–380 m³/h fresh · 180 Pa · 72 kg · Full Inverter · HEPA H13
Indicative coverage: ~180–280 m² depending on conditions
For large residential and small commercial installations: multi-room homes, large basements, medium healthcare facilities, boutique hotels, multi-zone offices, educational facilities. Variable power 1100–1860 W, R-32 × 850 g. Noise below 35 dB(A).
Coverage figures are indicative for typical residential and small-commercial conditions (moderate moisture load, 2.5–3.5 m ceilings, ordinary air exchange). The actual choice depends on starting and target humidity, ceiling height, infiltration and whether fresh-air intake runs continuously or by CO₂. For basements with active groundwater, indoor pools, hot tubs and specialised medical applications — request precise project sizing.
Which model should I choose?
The main selection variables: floor area / room volume, target fresh-air flow and acoustic requirements.
| Selection criterion | DD-36F | DD-56F | DD-96F | DD-136F |
|---|---|---|---|---|
| Capacity | 32–44 L/day | 45–75 L/day | 98–145 L/day | 110–155 L/day |
| Supply airflow | 410–500 m³/h | 450–600 m³/h | 650–870 m³/h | 800–1150 m³/h |
| Fresh-air flow | 0–200 m³/h | 0–200 m³/h | 0–300 m³/h | 0–380 m³/h |
| Static pressure | 120 Pa | 120 Pa | 150 Pa | 180 Pa |
| Noise (1 m) | < 32 dB(A) | < 32 dB(A) | < 35 dB(A) | < 35 dB(A) |
| Indicative coverage | ~50–90 m² | ~80–130 m² | ~130–200 m² | ~180–280 m² |
| Best for | Studios, small consulting rooms, single bedrooms, allergy-sensitive rooms | Family apartments, small clinics, classrooms, asthma-sensitive environments | Large homes, basements, clinics, server rooms, hotel suites | Multi-room homes, boutique hotels, offices, healthcare facilities |
Where is the DD-F Series used?
The series is designed for the residential and small-commercial range, where compact installation, single-phase supply, fresh-air management and anti-allergen filtration matter more than raw capacity:
Application guide
| Application | Target humidity | Typical needs | Recommended models |
|---|---|---|---|
| Residential — small apartments and studios | 45–55% | Compact installation; quiet operation; anti-allergen-grade air | DD-36F · DD-56F |
| Residential — family and large homes | 45–55% | Whole-house ductwork; fresh-air intake; quiet bedrooms | DD-56F · DD-96F · DD-136F |
| Residential basements | 50–60% | Higher moisture load; condensation prevention; mould risk | DD-96F · DD-136F |
| Small indoor pools and spa areas | 50–60% | High latent load from open water; fresh air equally essential; quiet operation next to relaxation areas | DD-96F · DD-136F |
| Healthcare — dental and general clinics | 40–55% | Anti-allergen HEPA H13 filtration; CO₂ control in waiting rooms | DD-56F · DD-96F |
| Small offices and retail | 45–55% | Fresh-air intake; CO₂ management; quiet operation | DD-56F · DD-96F · DD-136F |
| Classrooms and education | 45–55% | CO₂ control in occupied spaces; allergen filtration | DD-96F · DD-136F |
| Allergy-sensitive rooms (children, asthma) | 40–50% | HEPA H13 essential; low noise; fresh air with PM2.5 control | DD-36F · DD-56F · DD-96F |
| Small server rooms | 40–50% | Continuous operation; HEPA against dust; tight RH range | DD-56F · DD-96F |
| Boutique hotels and hospitality | 45–55% | Multi-zone distribution; fresh air to every room; quiet operation | DD-96F · DD-136F |
Fresh-air management — the full explanation
The defining feature of the DD-F Series — versus the DD Series and conventional dehumidifiers — is the automatic fresh-air valve paired with the 5-in-1 sensor. This section explains how it works, why it matters and where its limits lie.
Two inlets, one outlet. Every unit has two air inlets and one supply outlet. The first inlet (200 mm round duct) draws return air from the room; the second (150 mm) draws fresh outdoor air through a separate external wall connection. Inside the unit an automatic motorised damper varies the mix of recirculation and outdoor air. The combined stream passes through G4, then HEPA H13, then the evaporator coil (dehumidification), then the UV lamp and anion generator (purification), and is delivered through the 200 mm outlet.
CO₂-driven. The sensor measures CO₂ concentration continuously. When the threshold is exceeded (typical residential setting 800–1000 ppm; clinical 600–800 ppm), the damper opens to admit outdoor air and dilute CO₂ below the threshold. When it falls, the damper closes — recirculation only, with no unnecessary outdoor heating or cooling load. Threshold values are adjustable via the digital controller and the Wi-Fi app.
What does it replace? Without the DD-F, a comparable result requires three separate systems: a standalone dehumidifier, an energy-recovery ventilator (ERV) for fresh-air intake and a HEPA-grade air purifier. The DD-F integrates all three functions in one ceiling unit — single-phase supply, one 200 mm supply duct, one set of grilles in the room.
For installations that require full heating or cooling alongside dehumidification and fresh air — see the DD-FX Series for integrated climate control.
Fresh air or recirculation — your choice. The DD-F works as a fresh-air supply unit or as a pure recirculation dehumidifier. For recirculation-only operation, select dehumidification mode and leave the outdoor duct unconnected or keep the damper closed: the unit draws room air, dehumidifies it, filters it through HEPA and returns it — with no outdoor-air intake and its loads. Useful where a separate ventilation system handles fresh air, where outdoor air quality is temporarily poor, or where minimum energy consumption is the priority. Switching to fresh-air mode is simply opening the damper and selecting automatic mode. Manual override: the valve can be set manually — fully closed for maximum energy efficiency in harsh outdoor conditions, fully open for purge ventilation, or at a fixed position for a defined air-change rate.
How does DD-F compare with the alternatives?
The DD-F occupies a specific niche: compact ducted dehumidification with fresh air and HEPA on single-phase supply. Each common alternative has conditions where it is justified:
| Alternative | When it beats DD-F | When DD-F is better |
|---|---|---|
| DD Series (ducted, no fresh air or HEPA, three-phase) | Higher capacity needed (above 155 L/day); three-phase supply available; no fresh-air or HEPA requirement; lower equipment cost per litre. | Single-phase site; fresh-air management needed (CO₂ control); anti-allergen-grade HEPA H13 needed; smaller residential/commercial scale. |
| HRV / ERV system (heat-recovery ventilation) | Continuously high fresh-air rates in cold climates where exhaust heat recovery matters for the energy balance; new construction with budget for both systems. | Dehumidification is the primary requirement; HEPA filtration needed; single-unit ceiling installation; allergy-sensitive applications. |
| Wall- or floor-mounted unit (DanVex DEH-WP Series) | No ceiling void available; budget-sensitive single-room installation; mobile need. | Distribution to several rooms from one unit; concealed installation (aesthetics); fresh-air management needed; HEPA-grade filtration needed. |
| Standalone HEPA purifier + separate dehumidifier | A dehumidifier is already installed; very small scale where one room is sensitive and humidity is handled centrally. | An integrated solution with one ceiling unit, one duct network and one controller; whole-house or multi-room scale; strict aesthetics; less maintenance in the long run. |
| DD-FX Series (full climate control with heating/cooling) | Heating and cooling needed (climate control); precise low-temperature cooling (beverage cellar, server room); humidification needed. | Heating/cooling provided by other systems (radiators, central air conditioning); the lower price and simpler installation of the DD-F are sufficient. |
Key technologies — at a glance
- Automatic fresh-air valve — a motorised damper varies the mix of return air (200 mm inlet) and fresh outdoor air (150 mm inlet) under control of the 5-in-1 sensor; fresh-air flow 0–200 m³/h (DD-36F / DD-56F), 0–300 m³/h (DD-96F), 0–380 m³/h (DD-136F)
- HEPA H13 filtration — second stage after the G4 pre-filter, captures ≥ 99.95% of MPPS particles including pollen, mould spores, bacteria, fine dust and PM2.5
- 5-in-1 air quality sensor — continuous monitoring on the return stream; adjusts the fresh-air valve and operating mode by CO₂, PM2.5, TVOC, humidity and temperature
- Full Inverter across the range — inverter compressor, inverter fan and EEV as one system: continuously variable output to the actual load, no humidity swings and lower consumption
- Hot Gas Defrost — a fast defrost cycle versus around 30 minutes for natural defrost; operation from +5 °C with no appreciable capacity loss
- E-Coating on the heat exchanger across the range — an electrochemical layer resistant to moisture, salt vapour, mild acids and cleaning agents
- Pyramid-profile acoustic insulation — the housing lining absorbs compressor vibration rather than merely containing it, for quiet operation in occupied rooms
- Slide-out service module — compressor, main board, exchangers and refrigerant piping in one cassette; module exchange in about 15 minutes
- UV lamp + anion generator + Antifungus treatment — standard across the range
Technical specifications — DD-F Series
| Parameter | DD-36F | DD-56F | DD-96F | DD-136F |
|---|---|---|---|---|
| Dehumidification capacity (30 °C / 80% RH) | 32–44 L/day | 45–75 L/day | 98–145 L/day | 110–155 L/day |
| Supply airflow | 410–500 m³/h | 450–600 m³/h | 650–870 m³/h | 800–1150 m³/h |
| Return airflow | 410–500 m³/h | 450–600 m³/h | 570–870 m³/h | 770–1150 m³/h |
| Fresh-air flow | 0–200 m³/h | 0–200 m³/h | 0–300 m³/h | 0–380 m³/h |
| External static pressure | 120 Pa | 120 Pa | 150 Pa | 180 Pa |
| Rated power | 460–850 W | 550–970 W | 920–1260 W | 1100–1860 W |
| Current | 2.0–3.8 A | 2.5–4.4 A | 4.1–5.7 A | 5.0–8.5 A |
| Refrigerant | R-32 × 550 g | R-32 × 600 g | R-32 × 720 g | R-32 × 850 g |
| Noise level (1 m) | < 32 dB(A) | < 32 dB(A) | < 35 dB(A) | < 35 dB(A) |
| Dimensions (L×W×H) | 1160×590×325 mm | 1160×590×325 mm | 1200×640×370 mm | 1200×640×370 mm |
| Net / gross weight | 62 / 67 kg | 67 / 72 kg | 69 / 74 kg | 72 / 77 kg |
| Operating humidity range | 45–100% RH | |||
| Operating temperature range | +5…+38 °C | |||
| Voltage / frequency | 220–230 V single-phase / 50–60 Hz | |||
| Compressor | Inverter (Full Inverter) | |||
| Heat-exchanger protection | E-Coating | |||
| Defrost system | Hot Gas Defrost | |||
| Filtration | G4 pre-filter + HEPA H13 final | |||
| Air purification | UV sterilisation + anion generator | |||
| Internal Antifungus treatment | Yes | |||
| Air quality sensor | 5-in-1: CO₂ · PM2.5 · TVOC · RH · T° | |||
| Fresh-air valve | Automatic by CO₂ · manual override | |||
| Return / supply duct | Ø 200 mm round | |||
| Fresh-air duct | Ø 150 mm round | |||
| Connectivity | Wi-Fi + Modbus RTU RS-485 | |||
Frequently asked questions
What is the ideal indoor humidity level for a home?
Why do modern homes need fresh-air ventilation in addition to dehumidification?
What CO₂ level should healthy indoor air target?
What does HEPA H13 actually filter and when do I need it?
How quiet is a residential dehumidifier?
What is the difference between a dehumidifier and an air conditioner for humidity control?
Explore further
Ducted dehumidifiers — overview and selection guide →
DD Series — high capacity 140–960 L/day, three-phase →
DD-FX Series — Split System climate control with heating, cooling and humidification →
DEH-WP Series — wall- and floor-mounted, non-ducted →
DEH-1000P — mobile commercial unit, no installation →