About the range
Ducted dehumidification is a class of equipment installed out of sight — in a ceiling void, service shaft or plant area — and connected to the served space through ductwork; in the finished room the unit is invisible. Unlike portable and wall-mounted units, a ducted unit is part of the building services: it draws return air through one or more inlets, dehumidifies and filters the flow, and delivers dry air through one or more supply outlets. It is the standard solution wherever aesthetics, acoustic comfort or controlled multi-room distribution matter — residential interiors, commercial premises, healthcare, food production halls and large-volume industrial environments.
DanVex organises ducted dehumidification into three complementary series. The DD Series covers high-capacity commercial and industrial applications from 140 to 960 L/day on three-phase 380–415 V, with E-Coating heat-exchanger protection for aggressive environments. The DD-F Series is the compact residential and small-commercial line: 32–155 L/day on single-phase 220–230 V, with an automatic fresh-air valve (blending outdoor intake with recirculation) and HEPA H13 filtration for spaces with high air-quality requirements. The DD-FX Series is a full climate-control system: a split architecture (indoor unit + outdoor condenser) combining ducted dehumidification with heat-pump heating and cooling, adiabatic humidification and three-stage filtration up to HEPA H13.
Engineering standards across the range
Several engineering decisions are shared by every model in all three series — the things that define a DanVex ducted unit regardless of series:
Full Inverter + EEV
Full Inverter technology pairs an inverter compressor with an inverter-controlled fan and an electronic expansion valve (EEV). Compressor and fan continuously adjust output to the actual load and stabilise airflow, while the EEV meters refrigerant precisely — keeping the refrigerant circuit at peak efficiency and capacity across the whole operating range.
Concealed Ultra-Slim housing
A compact format designed for installation in ceiling voids and plant areas. The unit disappears into the building structure; only the intake and supply grilles are visible in the finished room. The robust powder-coated steel housing also allows outdoor installation where required.
Positive-pressure drainage
The condensate system works under positive pressure: it prevents water standing in the unit and drain line, eliminates air locks and stagnant zones, and blocks sewer odours entering through the drain in case of a faulty connection.
Modbus RTU RS-485 + Wi-Fi
Two independent remote-control channels on every model: Modbus RTU RS-485 for BMS and SCADA integration, and Wi-Fi for control and monitoring via the app. Auto-restart keeps all settings after a power failure.
5-in-1 air sensor
A built-in return-air sensor measures CO₂, PM2.5, TVOC, relative humidity and temperature. The unit automatically adapts its operation to the indoor air quality, not just the humidity set-point — without manual intervention.
UV + Anion + Antifungus
Internal UV lamp with antimicrobial Antifungus treatment keep the environment inside the unit and air paths sterile, preventing biofilms and microbial growth. The anion generator enriches the supply air with negative ions for a fresher indoor feel.
Digital controller
A touch-screen controller shows operating mode, sensor readings, fault diagnostics and set-points — humidity, temperature and fresh-air valve position where applicable. A filter-replacement timer alerts the operator to scheduled maintenance.
How to choose — decision guide
Function and capacity together determine the choice: what the installation must do — pure dehumidification, dehumidification with fresh-air management, or full climate control — and at what capacity. Select the series by function, then size the capacity within it.
| Your situation | Recommended series | Why |
|---|---|---|
| Compact residential or small commercial space; allergy sensitivity or medical requirement; need for automatic outdoor-air intake by CO₂ | DD-F Series | Single-phase 220–230 V, 32–155 L/day, CO₂-driven automatic fresh-air valve, medical-grade HEPA H13 filtration, Full Inverter and Hot Gas Defrost |
| Large commercial or industrial space; permanent installation on three-phase supply; focus on high-capacity dehumidification and basic ventilation | DD Series | Three-phase 380–415 V, 140–960 L/day, E-Coating heat exchanger, high static pressure 200–400 Pa for long duct runs, G4 + F7 filtration |
| One installation must combine dehumidification, heating, cooling, ventilation and humidification — luxury residential, beverage cellars, server rooms, laboratories, boutique commercial | DD-FX Series | Split architecture (indoor + outdoor units), 92–360 L/day dehumidification, heat-pump cooling and heating (operating range +6…+48 °C), adiabatic humidification module (2–8 kg/h), G4 + F7 + HEPA H13 filtration |
The DanVex ducted range
DD Series — high capacity 140–960 L/day · 1700–11 000 m³/h · 380–415 V · R-32 · E-Coating · 200–400 Pa
For commercial and industrial applications: indoor pools, spas, warehouses, food production, plant growing, museums, archives, public buildings. Full Inverter with EEV; Hot Gas Defrost; G4 + F7 filtration with UV + Anion + Antifungus; 5-in-1 sensor; Modbus RTU RS-485 + Wi-Fi. Single inlet / single outlet; integrates into central ventilation or works standalone. Models: DD-168 / DD-240 / DD-380 / DD-480 / DD-720 / DD-960.
DD-F Series — compact · fresh air + HEPA 32–155 L/day · 410–1150 m³/h · 220–230 V · R-32 · HEPA H13 · 120–180 Pa
For residential, small commercial, healthcare and air-quality-critical spaces. An automatic fresh-air valve blends outdoor intake with recirculation by CO₂; G4 + HEPA H13 filtration; Full Inverter; Hot Gas Defrost; UV + Anion + Antifungus; 5-in-1 sensor. Two inlets (recirculation + outdoor) and one supply outlet. Models: DD-36F / DD-56F / DD-96F / DD-136F.
DD-FX Series — climate control system 92–360 L/day dehumidification · 5.4–21 kW cooling · 5.9–24 kW heating · 350–1800 m³/h · Split System · R-32 · E-Coating · IPX4
A Split System architecture combines ducted dehumidification with heat-pump cooling and heating (operating range +6…+48 °C), an adiabatic humidification module (2–8 kg/h), three-stage G4 + F7 + HEPA H13 filtration and UV + Anion + Antifungus. For luxury residential, radiant cooling systems, wine and champagne cellars, server rooms, laboratories, healthcare and boutique commercial. Dehumidifies without raising supply-air temperature — critical for the Gulf climate. Models: DD-136FX / DD-168FX / DD-240FX / DD-380FX / DD-480FX / DD-720FX / DD-960FX.
Find by application
| Application | Recommended series |
|---|---|
| Residential basements and large homes | DD-F (compact) or DD-FX (with climate control) |
| Indoor pools and spas | DD Series (E-Coating heat exchanger for chlorine-laden air) |
| Wine and champagne cellars | DD-FX (low-temperature cooling down to +6 °C) |
| Server rooms and data centres | DD-FX (precise humidity + low-temperature cooling) |
| Medical and dental clinics | DD-F (with HEPA H13) or DD-FX (HEPA + climate) |
| Cleanrooms and laboratories | DD-FX (HEPA filtration + climate precision) |
| Food production halls | DD Series (E-Coating for aggressive environments) |
| Warehouses and logistics centres | DD Series (high static pressure for long runs) |
| Plant growing (indoor cultivation) | DD Series (high capacity) or DD-FX (climate + humidity) |
| Museums, archives, libraries | DD Series (humidity control without climate) |
| Boutique commercial (hotels, spas, wellness) | DD-FX Series |
| Educational facilities (classrooms) | DD-F Series (fresh air + HEPA + CO₂ control) |
Find by capacity
| Required capacity | Compact + fresh air | High capacity | Climate control |
|---|---|---|---|
| 30–100 L/day | DD-36F · DD-56F | — | DD-136FX |
| 100–200 L/day | DD-96F · DD-136F | DD-168 | DD-168FX · DD-240FX |
| 200–300 L/day | — | DD-240 | DD-380FX · DD-480FX |
| 300–500 L/day | — | DD-380 · DD-480 | DD-720FX · DD-960FX |
| 500–1000 L/day | — | DD-720 · DD-960 | — |
Capacities are measured at 30 °C / 80% RH (the industry-standard test condition). Actual capacity depends on ambient and operating conditions. For precise sizing, contact us with room dimensions, target humidity, moisture sources and operating temperature.
Engineering information
The DanVex ducted range is built on standards professional HVAC and BMS contractors rely on:
- BMS-ready — Modbus RTU RS-485 + Wi-Fi connectivity standard on every model across the three series; direct SCADA integration without protocol gateways
- 5-in-1 air sensor — measures CO₂, PM2.5, TVOC, humidity and temperature on the return-air stream; every reading available locally and over Modbus
- Static pressure for long runs — 120–180 Pa on DD-F (residential), 200–400 Pa on the DD Series (industrial), 180–300 Pa on DD-FX (climate system); sufficient for extended networks and multi-room distribution
- Pre-configured commissioning — units ship with all sensors, controller, UV + Anion modules, Antifungus treatment, filters and refrigerant charge; on site only the electrical connection by a certified electrician, condensate drain and duct connections remain
- R-32 refrigerant as standard — high thermodynamic efficiency at ducted-unit capacities
- Technical documentation — full datasheets, wiring diagrams, dimensional drawings and BMS integration notes available to qualified contractors on request
- Engineering support — project moisture-load calculations and on-site assistance through the dealer network, including the UAE with the Dubai warehouse