About the AD Industrial Series
The AD Industrial Series takes adsorption dehumidification to factory scale. The models cover capacities from 5 kg/h (AD-800) to 36 kg/h (AD-5000), all on three-phase 380–415 V. Process airflow from 820 to 5000 m³/h at 200 Pa static pressure on the AD-800/1000/1500 and 600 Pa on the AD-3000/5000 — sufficient for facility-wide ductwork and integrated air handling. Regeneration by electric heater (30 kW on the AD-3000; 60 kW on the AD-5000). The process and regeneration streams are handled by two independent centrifugal fans with a belt-driven rotor — the standard configuration of industrial adsorption equipment, with simplified rotor access through a single service door.
The series divides naturally into two tiers. The AD-800, AD-1000 and AD-1500 are the workhorse tier: powder-coated steel housings, a touch-screen controller with RS-485, G4 panel filter, IPX3 protection, IP54 fan motors with Class F insulation, and a −20…+40 °C range. The AD-3000 and AD-5000 are the premium tier: a polyurethane double-wall housing in a thermal-bridge-free aluminium frame, a condensation-free surface in normal operation, a programmable PLC with a 7″ screen and a range extended to +60 °C ambient (the wider range matters for hot ducted installations and AHU-integrated duty). Industrial-grade circuit components and relays from established European companies on every model. The rotor is from Proflute; a 5–8-year life in non-corrosive service with regeneration below 140 °C — the regime DanVex AD units are designed to run in.
Models in the range
DanVex AD-800 5 kg/h · 820 m³/h process / 250 m³/h regeneration · 200 Pa · 9 kW · 165 kg · < 70 dB · IPX3
Entry to the industrial tier. For mid-scale cold storage, food production with low humidity targets and medium pharmaceutical applications.
Touch-screen controller with RS-485; G4 panel filter; powder-coated steel housing.
DanVex AD-1000 7 kg/h · 1100 m³/h process / 400 m³/h regeneration · 200 Pa · 12 kW · 175 kg · < 70 dB · IPX3
The mid industrial tier. A common choice for medium pharmaceutical cleanrooms, mid-sized dry rooms and food lines with steady moisture loads.
Touch-screen controller with RS-485; G4 panel filter; powder-coated steel housing.
DanVex AD-1500 11 kg/h · 1550 m³/h process / 580 m³/h regeneration · 200 Pa · 13 kW · 190 kg · < 70 dB · IPX3
The upper-mid tier. For larger pharmaceutical facilities, large cold stores and food production with high-humidity processes.
Touch-screen controller with RS-485; G4 panel filter; powder-coated steel housing.
DanVex AD-3000 21.6 kg/h · 3000 m³/h process / 990 m³/h regeneration · 600 Pa · 33.84 kW (incl. 30 kW heater) · 350 kg · < 80 dB · IPX3
The premium tier. Large pharmaceutical cleanrooms, lithium-battery and semiconductor dry rooms, ice rinks, large cold storage.
Programmable PLC + 7″ touch screen · polyurethane double-wall housing · thermal-bridge-free aluminium frame · operating range up to +60 °C.
DanVex AD-5000 36 kg/h · 5000 m³/h process / 1650 m³/h regeneration · 600 Pa · 67.1 kW (incl. 60 kW heater) · 450 kg · < 80 dB · IPX3
The top of the industrial range. Factory-scale dry rooms, large ice rinks, multi-zone pharmaceutical facilities, large freeze-drying installations.
Programmable PLC + 7″ touch screen · polyurethane double-wall housing · thermal-bridge-free aluminium frame · operating range up to +60 °C.
Which model should I choose?
Capacity and tier drive the choice. The AD-800…AD-1500 share one engineering platform and scale by airflow and rotor size. The AD-3000 and AD-5000 are the premium tier; both have the PLC, the double-wall housing and the extended range, and the difference between them is pure capacity.
| Criterion | AD-800 | AD-1000 | AD-1500 | AD-3000 | AD-5000 |
|---|---|---|---|---|---|
| Capacity¹ | 5 kg/h | 7 kg/h | 11 kg/h | 21.6 kg/h | 36 kg/h |
| Process airflow | 820 m³/h | 1100 m³/h | 1550 m³/h | 3000 m³/h | 5000 m³/h |
| Operating temperature | −20…+40 °C | −20…+40 °C | −20…+40 °C | −20…+60 °C | −20…+60 °C |
| Total power | 9 kW | 12 kW | 13 kW | 33.84 kW | 67.1 kW |
| Controller | Touch screen + RS-485 | Touch screen + RS-485 | Touch screen + RS-485 | PLC + 7″ screen | PLC + 7″ screen |
| Housing | Powder-coated steel | Powder-coated steel | Powder-coated steel | Double-wall + thermal-bridge-free | Double-wall + thermal-bridge-free |
| Typical use | Medium cold store, medium pharma | Pharmaceutical cleanroom, medium dry room | Larger pharma, large cold store | Battery dry room, ice rink, large pharma | Factory-scale dry room, large rink |
¹ Capacity measured at 20 °C / 60% RH (the standard test condition for adsorption units). Actual capacity depends on inlet temperature and humidity, airflow rate and regeneration temperature. For projects with non-standard conditions, contact us — sizing is calculated in the original Proflute rotor-selection software with full thermodynamic modelling of the process and regeneration streams.
Where is the AD Industrial Series used?
Application guide
| Application | Recommended model | Notes |
|---|---|---|
| GMP-grade pharmaceutical cleanroom or dry room, target dew point below 0 °C | AD-1000 to AD-3000 | PLC with 7″ screen on the AD-3000 for point logging and audit trail; Modbus RTU into the facility BMS |
| Lithium-battery or semiconductor dry room, 1% RH target, dew point below −40 °C | AD-3000 or AD-5000 | The premium tier is required: thermal-bridge-free housing and PLC control. Sizing in the Proflute software |
| Ice rink — preventing condensation on the roof structure and seating | AD-3000 or AD-5000 | Continuous high-capacity operation; dew point well below ice temperature; ducted distribution along the roof |
| Food production with low humidity targets — powders, confectionery, freeze-drying, spices | AD-800 to AD-3000 | G4 panel filter standard; IPX3 protection; resistant or painted housing acceptable for food-adjacent environments |
| Large cold storage / freezer warehouse, sub-zero dehumidification | AD-1500 to AD-5000 | Adsorption runs continuously at −20 °C where condensation stops; ducted distribution from the entrance airlock |
| Plant growing — specialised low-humidity crops (seed drying, post-harvest storage) | AD-1000 to AD-3000 | Modbus RTU for integration with the grow-room controller; 5–8-year rotor life and stable performance over years of service |
| Plastic injection moulding — drying hygroscopic polymer pellets (PA, PET) | AD-800 to AD-1500 | Continuous supply of low-dew-point air to hopper dryers; sizing tied to throughput |
How does AD Industrial compare with the market?
Against budget adsorption units at industrial capacities — cheaper imports without a documented rotor source or proper sealing — the AD Industrial differs in rotor manufacturer, housing engineering and control depth.
| Feature | DanVex AD Industrial | Budget adsorption |
|---|---|---|
| Rotor manufacturer | ✓ Proflute | ✗ unnamed OEM rotor |
| Thermal-bridge-free housing | ✓ AD-3000 / AD-5000 (double-wall) | ✗ standard panel only |
| Ducted operation | ✓ full duct integration | ~ limited ducting |
| Installation outside the dried room | ✓ yes — ducted to the space | ~ single-fan units inside the room |
| Operation above +40 °C ambient | ✓ up to +60 °C (AD-3000 / AD-5000) | ✗ rated to +40 °C maximum |
| Controller | ✓ PLC + 7″ screen on the upper tier | ~ basic controller |
Key technologies — at a glance
Proflute rotor + sizing software
The rotor is from Proflute — one of the two leading European manufacturers of adsorption rotors. A stable adsorption curve and a 5–8-year life in non-corrosive service. Every project is sized in the original Proflute rotor-selection software — thermodynamic modelling of the process and regeneration streams, not room-volume rules of thumb.
Two fans + belt-driven rotor
Two independent centrifugal fans for process and regeneration; room pressure preserved. The rotor is belt-driven by a small geared motor (0.1 kW; 1:800 reduction on the AD-3000 and 1:1200 on the AD-5000) — the standard industrial configuration with rotor service through a single access door.
Thermal-bridge-free double-wall housing
The AD-3000 and AD-5000 feature a double-wall panel with injected polyurethane foam and a thermal-bridge-free aluminium frame with a thermal break. The housing surface stays condensation-free in normal operating conditions — eliminating the recurring moisture problem of standard AHU casings in cold or humid service.
Programmable PLC + 7″ touch screen
The AD-3000 and AD-5000 include an industrial-grade PLC with customisable set-points, schedules and alarm thresholds and full telemetry over RS-485. A 7″ touch screen on the cabinet door for local operation. Industrial-grade circuit components and relays from established European companies.
Modbus RTU RS-485
BMS integration is standard on every model. The unit appears on the BMS or SCADA as a Modbus slave — humidity set-point, current readings, regeneration-heater status, alarms and run-hour counters, all over RS-485 without a protocol gateway.
G4 panel filter + IPX3 protection
A G4 panel filter (EN 779:2012) in an aluminium-alloy frame ahead of the rotor — coarse and medium particles are removed before reaching the silica gel. IPX3 housing rating; fan motors with IP54 protection and Class F insulation across the series.
Technical specifications — AD Industrial Series
| Parameter | AD-800 | AD-1000 | AD-1500 | AD-3000 | AD-5000 |
|---|---|---|---|---|---|
| Capacity¹ | 5 kg/h | 7 kg/h | 11 kg/h | 21.6 kg/h | 36 kg/h |
| Operating temperature | −20…+40 °C | −20…+40 °C | −20…+40 °C | −20…+60 °C | −20…+60 °C |
| Process airflow | 820 m³/h | 1100 m³/h | 1550 m³/h | 3000 m³/h | 5000 m³/h |
| Process static pressure | 200 Pa | 200 Pa | 200 Pa | 600 Pa | 600 Pa |
| Regeneration airflow | 250 m³/h | 400 m³/h | 580 m³/h | 990 m³/h | 1650 m³/h |
| Regeneration static pressure | 150 Pa | 150 Pa | 150 Pa | 400 Pa | 400 Pa |
| Total power | 9 kW | 12 kW | 13 kW | 33.84 kW | 67.1 kW |
| Current | 13.6 A | 18 A | 20 A | 52 A | 89 A |
| Process air duct | Ø 200 mm | Ø 200 mm | Ø 250 mm | Rectangular flange 500×300 mm | Rectangular flange 630×450 mm |
| Regeneration duct | Ø 150 mm | Ø 150 mm | Ø 160 mm | Rectangular flange 200×200 mm | Rectangular flange 300×300 mm |
| Controller | Touch screen + RS-485 | Touch screen + RS-485 | Touch screen + RS-485 | PLC + 7″ screen + RS-485 | PLC + 7″ screen + RS-485 |
| Housing | Powder-coated steel | Powder-coated steel | Powder-coated steel | Double-wall + thermal-bridge-free frame | Double-wall + thermal-bridge-free frame |
| Dimensions (L×W×H) | 640×877×1232 mm | 640×877×1232 mm | 660×888×1238 mm | 2455×1240×1420 mm | Per project (verified) |
| Net weight | 165 kg | 175 kg | 190 kg | 350 kg | 450 kg |
| Noise level (1 m) | < 70 dB(A) | < 70 dB(A) | < 70 dB(A) | < 80 dB(A) | < 80 dB(A) |
| Operating humidity range | 1–100% RH | ||||
| Voltage / frequency | 380–415 V / 50–60 Hz · three-phase | ||||
| Process air filter | G4 (EN 779:2012) | ||||
| Housing rating | IPX3 | ||||
| Fan motor | IP54 / Class F insulation | ||||
| BMS protocol | Modbus RTU RS-485 | ||||